Topics on this page
Security update connectivity
Verify the connectivity between the relay server and its Active Update source or proxy server:
-
To verify that both a route exists and that the relay port number is open, enter the command:
telnet [relay IP] [port number]
If the telnet fails, verify that a route exists and that firewall policies (if any) allow the traffic by pinging or using traceroute. Also verify that the port number is open, and does not have a port conflict.
-
To verify that the DNS server can resolve the domain name of the relay, enter the command:
nslookup [relay domain name]
If the test fails, verify that the agent is using the correct DNS proxy or server (internal domain names cannot be resolved by a public DNS server such as Google or your ISP).
If you are using Workload Security, you might not be using your own relays; instead, you will be using the relays that are built into the service:
relay.deepsecurity.trendmicro.com
. -
If you use a proxy server, in Workload Security, confirm that the proxy settings are correct.
-
To determine if your Workload Security settings are blocking connectivity, unassign the current policy.